- Diagnostic Tools[6]
- Multimeters[5]
- Testing Equipment[6]
- Gasoline Generators[1]
- Battery Testers[2]
- Transformers[1]
- Emergency Tools[3]
- Other Vehicle Tools[5]
- Oscilloscopes[2]
- Clamps[3]
- Clamp Meters[1]
- Other Measuring & Analysing Instruments[1]
- Electric Soldering Irons[2]
- Other Vehicle Equipment[6]
- Gas Analyzers[6]
- Power Cables[2]
- Communication Cables[1]
- Other Lights & Lighting Products[1]
- Key[6]
- Vacuum Cleaner[2]
- Other Motorcycle Accessories[2]
- Other Car Cleaning Tools[4]
- Wheel Alignment[6]
- Tire Repair Tools[1]
- Tire Changers[6]
- Spray Booths[6]
- Car Lifts[6]
- Car Jacks[2]
- Scissors[1]
- Other Car Care Equipment[3]
- Car Washer[5]
- Other Car Care Products[1]
- Other Exterior Accessories[1]
- Tire Inflators[1]
- Contact Person : Ms. deng mandy
- Company Name : Shenzhen Zeus Technology Co., Ltd.
- Tel : 86-755-83266856-8009
- Fax : 86-755-83266856
- Address : Guangdong,Shenzhen,Room 1208-1217, 12/F,zhonghao building,Ba Gua Forth RD,Futian,Shenzhen,China
- Country/Region : China
- Zip : 518029
Related Product Searches:car exhaust gas analyzer MST-406EN 4 gas anylayzer,High Quality,car exhaust gas Emission Analyzer, 4 gas analyzer,MST-406EN
MST-406EN Automotive Emission Analyzer(4-Gas / Portable)
Main Features and Specifications
1. Measure concentration of HC, CO, CO2, O2 contained in exhaust gases from gasoline engine of vehicles. Advanced NDIR (non-Dispersive Infrared) analysis technology is used to measure HC, CO, CO2 and the newest generation of electrochemical technology is adopted to measure O2 . Designed with LCD screen for easier setting and operation.
2. Automatic calculation and display of A/F (air-fuel-ratio)
and Lambda air ratio λ.
3. Emissions from vehicle engine fuels of CNG, LPG and Ethanol gasoline can be measured.
4. Small Size, light weight and most convenient for carry.
5. Designed with inductive clip-on pickup sensor for RPM
measurement.
6. Designed with oil temperature measurement probe.
6. Designed with RS-232C digital serial interface.
7. 200 groups of measurement data storage and review.
8. In compliance with accuracy requirement of ISO 3930
or OIML R99 Class I.
Options and Accessories:
1. Micro printer.
2. Various RPM measurement adaptors.
3. DC12V vehicle power inverter.
Main Technical Specifications
Measuring Range:
HC: 0~9,999 ppm (n-Hexane)
CO: 0~10 %
CO2 : 0~18 % 2
O2 : 0~25 % 2
Response Time: Less than 10s for T90 (O2, less than 12s)
Warm-up Time: 10 min. (ambient temperature is not lower than 20°C)
Power Supply: AC220V ±10% 50Hz ±1Hz
Net Weight: 6.0Kg
Outer Dimension:260mm(W) × 180mm(H) × 450mm(D)
car exhaust gas analyzer MST-406EN 4 gas anylayzer